May
02

Training Advisory from a Police Department

By

In September of 2011 an officer was involved in a situation which quickly became a use of deadly force incident. When the officer made the decision to use deadly force, the chambered round in his duty pistol did not fire. Fortunately, the officer used good tactics, remembered his training and cleared the malfunction, successfully ending the encounter.

The misfired round, which had a full firing pin strike, was collected and was later sent to the manufacturer for analysis. Their analysis showed the following: “…the cause of the misfire was determined to be from the primer mix being knocked out of the primer when the round was cycled through the firearm multiple times”. The police department also sent an additional 2,000 rounds of the Winchester 9mm duty ammunition to the manufacturer. All 2,000 rounds were successfully fired.

In discussions with the officer, they discovered that since he has small children at home, he unloads his duty weapon daily. His routine is to eject the chambered round to store the weapon. Prior to returning to duty he chambers the top round in his primary magazine, then takes the previously ejected round and puts in back in the magazine. Those two rounds were repeatedly cycled and had been since duty ammunition was issued in February or March of 2011, resulting in as many as 100 chambering and extracting cycles. This caused an internal failure of the primer, not discernible by external inspection.

This advisory is to advise that repeated cycling of duty or training rounds is to be avoided. As a reminder, when loading the weapon, load from the magazine and do not drop the round directly into the chamber. If an officer’s only method of safe home storage is to unload the weapon, the Firearms Training Unit suggests that you unload an entire magazine and rotate those rounds. In addition, you should also rotate through all 3 duty magazines, so that all 52 duty rounds are cycled, not just a couple rounds. A more practical method of home storage is to use a trigger lock or a locked storage box.

Further Guidance from ATF Firearms Technology Branch:

The primer compound separation is a risk of repeatedly chambering the same round. The more common issue is bullet setback, which increases the chamber pressures often resulting in more negative effects.

Categories : Facebook

Leave a Reply

You must be logged in to post a comment.

Today’s Devotionals and Blogs

Kent Crockett’s blog – www.kentcrockett.blogspot.com

Mark Dillow’s blog – http://noclearline.blogspot.com/

NOAA Weather

Austin, Texas

Last Updated on May 30 2023, 12:53 pm CDT

Current Conditions: Partly Cloudy

NOAA Icon

Temp: 84°F

Wind: SE at 7mph

Humidity: 57%

Heat Index: 87°F

Your 5-Day Forecast at a Glance

Bible Verse of the Day

O LORD, You have searched me and known me. You know my sitting down and my rising up; You understand my thought afar off.

Calendar

 May 2023
SMTWTFS
30123456
78910111213
14151617181920
21222324252627
28293031123